Polimaster PM1710GNA 手持式γ和γ-n监测器
制造商: POLIMASTER Model: PM1710GNA 来源: EU - 报价要求
- 联系
- Standards compliance: ITRAP/IAEA requirements
- Search and spectrometry γ-channel
+ Detector: CsI(Tl)
+ Sensitivity for 137Сs, no less: 500 (s-1)/(μSv/h) (5.0 (s-1)/(μR/h))
+ Sensitivity for 241Am, no less: 500 (s-1)/(μSv/h) (5.0 (s-1)/(μR/h))
+ Energy range: 0.045 – 3.0 MeV
- Search neutron-channel
+ Detector: He-3
+ Sensitivity
for Pu - α-Be: 0.1 (counts·cm2)/neutron
for thermal neutrons: 7.0 (counts·cm2)/neutron
for Pu - α-Be on a phantom or in the moderator chamber: 1.0 (counts·cm2)/neutron
+ Energy range: 0.025 eV - 14 MeV
+ Indication range: 001 – 999 s-1
- Dimensions: 195 x 82 x 32 mm
- Weight : 650 g (22.9 oz)
- Drop test on concrete floor: 0.7 m (2.3 ft)
- Environmental protection: IP65
- Power: one AA battery/1000 hours
- PC Communication: IRDA
Include: PM1710GNA, Battery AA, Remote vibration alarm , Wrist band, IR communication adapter,Moderator chamber, Telescopic tube, Software on CD, Operation manual, User packing box
The PM1710A Hand-held Gamma and PM1710GNA Gamma-Neutron Monitors are highly sensitive instruments designed to detect and locate even the slightest traces of radioactive and nuclear materials. The PM1710A and PM1710GNA perform the following functions:
PM1710A | PM1710GNA | |
---|---|---|
Standards compliance |
ITRAP/IAEA requirements | ITRAP/IAEA requirements |
Search and spectrometry γ-channel | ||
Detector |
CsI(Tl) | CsI(Tl) |
Sensitivity for 137Сs, no less |
500 (s-1)/(μSv/h) (5.0 (s-1)/(μR/h)) | 500 (s-1)/(μSv/h) (5.0 (s-1)/(μR/h)) |
Sensitivity for 241Am, no less |
500 (s-1)/(μSv/h) (5.0 (s-1)/(μR/h)) | 500 (s-1)/(μSv/h) (5.0 (s-1)/(μR/h)) |
Energy range |
0.045 – 3.0 MeV | 0.045 – 3.0 MeV |
Indication range | 1 – 3000 · R/h (0.01 – 30· Sv/h) | 1 – 3000 · R/h (0.01 – 30· Sv/h) |
Accuracy of DER indication (at 137Сs) in the range of 0.1 – 20 µSv/h (10 – 2000 µR/h), no less |
± (20 + К/ Η ) %, where Η – is the indicated DER, К – a coefficient of 1 µSv/h |
± (20 + К/ Η ) %, where Η – is the indicated DER, К – a coefficient of 1 µSv/h |
The number of accumulation channels of the scintillation spectra |
||
The number of spectra, stored in non-volatile memory |
||
Search neutron-channel | ||
Detector |
He-3 | |
Sensitivity - for Pu - α-Be - for thermal neutrons - for Pu - α-Be on a phantom or in the moderator chamber |
0.1 (counts·cm2)/neutron 7.0 (counts·cm2)/neutron 1.0 (counts·cm2)/neutron |
|
Energy range |
0.025 eV - 14 MeV | |
Indication range | 001 – 999 s-1 | |
Measuring γ-channel | ||
Detector |
||
Dose rate |
||
Energy range |
||
Measuring α and β-channel | ||
Detector |
||
Measurement range of α-flux density |
||
Measurement range of β-flux density |
||
Energy range of β measuring |
||
Physical Parameters | ||
Dimensions |
172 x 57 x 32 mm | 195 x 82 x 32 mm |
Weight |
420 g (14.8 oz) | 650 g (22.9 oz) |
Drop test on concrete floor: |
0.7 m (2.3 ft) | 0.7 m (2.3 ft) |
Environmental Characteristics | ||
Temperature |
-30 to + 50 °C (-22 to +122 °F) | -30 to + 50 °C (-22 to +122 °F) |
Humidity |
up to 95 % at 35 °С (95 °F) | up to 95 % at 35 °С (95 °F) |
Environmental protection |
IP65 | IP65 |
Power | ||
Batteries |
one AA battery | one AA battery |
Battery lifetime |
1000 hours | 1000 hours |
PC Communication | ||
PC Communication | IRDA | IRDA |
Operation manuals:
- PM1710 Manual, 947.08 Kb
Software:
Software user guides:
- PM PRD (1703) software user guide, 273.16 Kb
Product Brochures:
Certificates:
- PM1710 ITRAP Certificate, 95.46 Kb
- PM1710 Certificate - Russia, 810.99 Kb
- 质量承诺
- 正品保修
- 送货到家
- 交易简单化