For full functionality of this site it is necessary to enable JavaScript.

Hioki MR8741 存储记录仪

Specification
- Number of channels:
  +  16 ch analog + 16 ch standard logic/[8 analog units]
  + 10 ch analog + 64 ch logic / [5 analog units + 3 logic units] 
- Measurement ranges: 
  + 5 mV to 20 V/div, 12 ranges, resolution : 1/100 of range
  + 5 mV to 50 V/div, 5 ranges, resolution : 1/50,000 of range 
- Max. allowable input: 400 V DC 
- Frequency characteristics: DC to 5MHz  
- Time axis: 5 μs to 5 min/div; 26 ranges; time axis resolution: 100 points/div
- Measurement functions: Memory (high-speed recording), FFT
- Memory capacity: :  16 MW/ch (fixed), total of 256 MW installed
- External storage: USB memory stick (USB 2.0)
- Display: None (1 digital DVI terminal per block, 800 × 600 dots)
- External interfaces: LAN, USB2.0
- Power supply: 100 to 240 V AC, 50/60 Hz (120 VA max.)
- Dimensions, mass:       350×160×320mm, 5.4 kg 
- Supplied accessories:        Instruction Manual ×1, Application Disk (Wave Viewer Wv, Communication Commands table) ×1, Power cord ×1
- The warranty period: 12 month
 

Details
  MR8740 MR8741
Number of channels [Block I: 16 analog units]
From 32 ch analog + 8 ch standard logic inputs
[Block I: 13 analog units + 3 logic units]
26 ch analog + 56 ch logic (8 ch standard logic + 48 ch logic unit)

[Block II: 11 analog units]
From 22 ch analog + 8 ch standard logic
[Block II: 8 analog units + 3 logic units]
16 ch analog + 56 ch logic (8 ch standard logic + 48 ch logic unit)
*Instrument consists of two blocks, Block I and Block II.
*Block I and Block II start measurement simultaneously by means of trigger synchronization (internal setting).
[8 analog units] From 16 ch analog + 16 ch standard logic
[5 analog units + 3 logic units] 10 ch analog + 64 ch logic (16 standard logic + 48 logic unit)
*Analog unit channels are isolated from each other and from chassis. Logic unit channels and standard logic terminal channels share a common GND with chassis.
Measurement ranges
(20 div full scale)
5 mV to 20 V/div, 12 ranges, resolution : 1/100 of range (when using 8966)
5 mV to 50 V/div, 5 ranges, resolution : 1/50,000 of range (when using MR8990)
Max. allowable input 400 V DC (when using 8966; upper limit voltage that can be applied between input terminals without damage)
Max. rated voltage to earth 300 V AC/DC (input and instrument are isolated; between input channels and chassis; upper limit voltage that can be applied between input channels without damage)
Frequency characteristics DC to 5 MHz (-3dB, when using 8966)
Time axis (MEMORY operation) 5 μs to 5 min/div; 26 ranges; time axis resolution: 100 points/div; time axis expansion: 3 stages from ×2 to ×10; compression: 13 stages from 1/2 to 1/20,000
Measurement functions Memory (high-speed recording), FFT
Memory capacity 16 MW/ch (fixed), total of 864 MW installed 16 MW/ch (fixed), total of 256 MW installed
External storage USB memory stick (USB 2.0)
Display None (1 digital DVI terminal per block, 800 × 600 dots) None (1 digital DVI terminal, 800 × 600 dots)
External interfaces [LAN] 100Base-TX (DHCP and DNS support, FTP server, HTTP server)
[USB] USB 2.0 Series A receptacle × 2 (mouse operation)
Power supply 100 to 240 V AC, 50/60 Hz (250 VA max.) 100 to 240 V AC, 50/60 Hz (120 VA max.)
Dimensions and mass 426 mm (16.77 in) W × 177 mm (6.97 in) H × 505 mm (19.88 in) D, 10.8 kg (381.0 oz) (main unit only) 350 mm (13.78 in) W × 160 mm (6.30 in) H × 320 mm (12.60 in) D, 5.4 kg (190.5 oz) (main unit only)
Accessories Instruction Manual ×1, Application Disk (Wave Viewer Wv, Communication Commands table) ×1, Power cord ×1

Catalog

  • 质量承诺
  • 正品保修
  • 送货到家
  • 交易简单化

注册收新闻 - 获得优惠活动的机会