- 联系
                   
 AC Current range:     AC (RMS or Peak value)20.00 or 200.0 A AC, 2 ranges (±1.3 % rdg. ±3 dgt. at 50 or 60Hz), AC+DC (RMS or Peak value)20.00 or 200.0 A AC, 2 ranges (±1.3 % rdg. ±13 dgt. at 50 or 60Hz), Effective value rectifier
 DC Current range:     DC (Average or Peak value)20.00 or 200.0 A DC, 2 ranges (±1.3 % rdg. ±3 dgt.)
 AC Voltage range:     AC (RMS or Peak value)30.00 to 600 V AC, 3 ranges (±1.0 % rdg. ±3 dgt. at 50 or 60Hz), AC+DC (RMS or Peak value)30.00 to 600 V AC, 3 ranges (±1.0 % rdg. ±7 dgt. at 50 or 60Hz), Effective value rectifier
 DC Voltage range:     DC (Average or Peak value)30.00 to 600 VDC, 3 ranges (±1.0 % rdg. ±3 dgt.)
 Frequency Measurement: 10 to 1000 Hz, 2 ranges (±0.3 % rdg. ±1 dgt.)
 Frequency characteristics (at AC current / voltage):     DC, 10 to 2 kHz
 Max. Circuit Voltage: 600 V AC rms (insulated wire)
 Power Supply: 6F22(006P) × 1, Continuous use 25 hours, or AC adapter
 Core jaw dia.: Ø33 mm(1.3 in)
 Dimensions: 62 mm(2.44 in)W × 230 mm(9.06 in)H × 39 mm(1.54 in)D
 Weight: 460 g (16.2 oz)
 Accessories: 9207-10 TEST LEAD (1), 9399 CARRYING CASE (1), Hand strap (1)
  
| AC Current range: | AC (RMS or Peak value)20.00 or 200.0 A AC, 2 ranges (±1.3 % rdg. ±3 dgt. at 50 or 60Hz), AC+DC (RMS or Peak value)20.00 or 200.0 A AC, 2 ranges (±1.3 % rdg. ±13 dgt. at 50 or 60Hz), Effective value rectifier | 
| DC Current range: | DC (Average or Peak value)20.00 or 200.0 A DC, 2 ranges (±1.3 % rdg. ±3 dgt.) | 
| AC Voltage range: | AC (RMS or Peak value)30.00 to 600 V AC, 3 ranges (±1.0 % rdg. ±3 dgt. at 50 or 60Hz), AC+DC (RMS or Peak value)30.00 to 600 V AC, 3 ranges (±1.0 % rdg. ±7 dgt. at 50 or 60Hz), Effective value rectifier | 
| DC Voltage range: | DC (Average or Peak value)30.00 to 600 VDC, 3 ranges (±1.0 % rdg. ±3 dgt.) | 
| Frequency Measurement: | 10 to 1000 Hz, 2 ranges (±0.3 % rdg. ±1 dgt.) | 
| Analog Output: | None | 
| Frequency characteristics (at AC current / voltage): | DC, 10 to 2 kHz | 
| Display Section: | Current / 2500 dgt. Voltage / 3750 dgt. Bar graph / 35 seg | 
| Sampling Rate: | 2 or 4 times/sec (Slow: 1 times/3 sec) | 
| Crest Factor (RMS): | 2.5 (1.7 at 200 A range), 1.5 (200 A range) | 
| Max. Circuit Voltage: | 600 V AC rms (insulated wire) | 
| Power Supply: | 6F22(006P) × 1, Continuous use 25 hours, or AC adapter | 
| Core jaw dia.: | Ø33 mm(1.3 in) | 
| Dimensions: | 62 mm(2.44 in)W × 230 mm(9.06 in)H × 39 mm(1.54 in)D | 
| Weight: | 460 g (16.2 oz) | 
| Accessories: | 9207-10 TEST LEAD (1), 9399 CARRYING CASE (1), Hand strap (1) | 
- 质量承诺
- 正品保修
- 送货到家
- 交易简单化