Gastec 127 便携式气体检测管对二氯苯检测管C6H4Cl2(2.5~300 ppm)
制造商: Gastec Model: 127 - 联系
Indicator: 2.5 to 300 ppm
Measuring Range: 2.5 to 300 ppm, Number of Pump Strokes 2
Sampling Time: 1.5 minute per pump stroke
Colour Change: White → Light brown
Reaction Principle: C6H4Cl2 + I2O5 + H2S2O7 → I2
Coefficient of Variation: 10% (for 2.5 to 100 ppm), 5% (for 100 to 300 ppm)
Nr. of tests: 10
Pump: GV-100S/110S
Measuring Range | 2.5 to 300 ppm |
Number of Pump Strokes | 2 |
Correction Factor | 1 |
Sampling Time | 1.5 minutes per pump stroke |
Detecting Limit | 1 ppm (n=2) |
Colour Change | White → Light brown |
Reaction Principle | C6H4Cl2 + I2O5 + H2S2O7 → I2 |
Coefficient of Variation | 10% (for 2.5 to 100 ppm), 5% (for 100 to 300 ppm) |
Shelf Life | 3 Years |
Corrections for temperature & humidity | Temperature correction is necessary |
Store the tubes at cool and dark place. |
Substance | Concentration | Interference | Change colour by itself to |
Aromatic hydrocarbons | + | Light brown | |
Acetylene, Ethylene, Hexane | 0.2%![]() |
No | Light brown (whole layer)(![]() |
Carbon monoxide | 0.1%![]() |
No | Light brown (whole layer)(![]() |
Esters | 0.2%![]() |
No | Light brown (whole layer)(![]() |
Alcohols, Ketones | ![]() |
+ | No |
Substance | Correction Factor | No. of pump strokes | Measuring Range |
m-Dichlorobenzene | 1.0 | 2 | 2.5 to 300 ppm |
p-Dichlorobenzene | 1.0 | 2 | 2.5 to 300 ppm |
Calibration gas generation | Diffusion tube method |
TLV-TWA | TLV-STEL | Explosive range |
25 ppm(2014) | 50 ppm(2014) | 2.2 to 12% |
- 质量承诺
- 正品保修
- 送货到家
- 交易简单化