For full functionality of this site it is necessary to enable JavaScript.

Elcometer CG100B 腐蚀度测厚仪(0.01~508mm,Thrupaint 模式,B-Scan)

Measurement Mode: PE, PETP, EE, EEV, CT, PECT
Measurement Rate: 
+ 4 readings per second
+ 50 readings per second
+ 6 readings per second
Measuring Range
+ PE: 0.63 - 508mm 
+ PETP: 0.63 - 508mm 
+ EEV: 1.27 - 25.4mm 
+ PECT: 0.63 - 508mm 
+ PECT: 0.01 - 2.54mm 
Calibration Options: Single, two point, velocity & material type
Measurement Accuracy: ± 1% or ±0.1mm 
Measurement Resolution: 0.01 mm
Velocity Calibration Range: 1250 - 9,999m/s
 B-Scan display speed: 15 seconds per screen
Transducer Frequency Range: 1 - 10MHz
Display: 1/8 inch VGA, Display Refresh Rate 25Hz
Battery Type: 3 x AA alkaline
Battery Life: 150 hours
Operating Temperature: -10 to 60ºC
Size (w x h x d): 63.5 x 165.0 x 31.5mm
Weight (including batteries): 383g
RS232 Interface: Bi-directional
Packing List: Elcometer NDT CG100B gauge, couplant, carry case, user manual, test certificate, 3 x AA batteries

Note: A transducer is not suppied with the Gauges, must be ordered separately
 

Details

Manual

Datashet

Datasheet Transducer

CG100 Corrosion Thickness Gauges

With a wide selection of display and measurement modes, automatic gain control and data-logging, the CG100 range of corrosion thickness gauges is ideal for measuring coating and material thickness as well as for locating pits, flaws and defects in materials.

The Elcometer CG100 ultrasonic corrosion thickness gauge is available in four models - from an entry level CG100B to the top of the range CG100ABDL+.

 

CG100 Thickness Gauge

Features:

  • Range of display & measurement options: Pulse-Echo, Echo-Echo, Pulse-Echo Temp, Comp Mode (PETP), Coating Only Mode (CT), Pulse-Echo Coating Mode (PECT)
  • Adjustable gain: -30dB to 70dB range
  • Automatic gain control (AGC)
  • Time corrected gain (TCG)
  • Gate control
  • Threshold adjustment
  • 64 User defined setups
  • Multiple language display
  • Multiple calibration and material selection options
  • High speed scan mode: 32 readings per second
  • Differential and minimal thickness alarm modes
  • Data output and storage: 16,000 readings and waveforms or B-Scans
  • Download to ElcoMaster® data management software

 

 

CG100 Corrosion Thickness Gauges

Technical Specification

Model & Part Number

CG100B

CG100BDL

CG100ABDL

CG100ABDL+

Material thickness digits display

B-Scan cross sectional display

Combined B-Scan and digits display

Scan bar display

Coating thickness display

A-Scan Display

 

 

+ Rectified, - Rectified,
Full Waveform (RF)

+ Rectified, - Rectified,
Full Waveform (RF)

Measurement Mode

PE, PETP (Temp Compensation),
EE (ThruPaint™), EEV,
CT (Coating) & PECT

PE, PETP (Temp Compensation),
EE (ThruPaint™), EEV,
CT (Coating) & PECT 

PE, PETP (Temp Compensation),
EE (ThruPaint™), EEV,
CT (Coating) & PECT

PE, PETP (Temp Compensation),
EE (ThruPaint™), EEV,
CT (Coating) & PECT

Measurement Rate
Manual:
Scan mode
Scan bar display

4 readings per second
50 readings per second
6 readings per second

4 readings per second
50 readings per second
6 readings per second
 

4 readings per second
50 readings per second
6 readings per second
 

4 readings per second
32 readings per second
6 readings per second

Measuring Range

PE: 0.63 - 508mm
(0.025 - 19.999 inches)
PETP: 0.63 - 508mm
(0.025 - 19.999 inches)
EE: 1.27 - 102mm
(0.050 - 4.000 inches)
EEV: 1.27 - 25.4mm
(0.050 - 1.000 inches)
CT: 0.01 - 2.54mm
(0.001 - 0.100 inches)
PECT: 0.63 - 508mm
(0.025 - 19.999 inches)
PECT: 0.01 - 2.54mm
(0.001 - 0.100 inches) 

PE: 0.63 - 508mm
(0.025 - 19.999 inches)
PETP: 0.63 - 508mm
(0.025 - 19.999 inches)
EE: 1.27 - 102mm
(0.050 - 4.000 inches)
EEV: 1.27 - 25.4mm
(0.050 - 1.000 inches)
CT: 0.01 - 2.54mm
(0.001 - 0.100 inches)
PECT: 0.63 - 508mm
(0.025 - 19.999 inches)
PECT: 0.01 - 2.54mm
(0.001 - 0.100 inches)  

PE: 0.63 - 508mm
(0.025 - 19.999 inches)
PETP: 0.63 - 508mm
(0.025 - 19.999 inches)
EE: 1.27 - 102mm
(0.050 - 4.000 inches)
EEV: 1.27 - 25.4mm
(0.050 - 1.000 inch)
CT: 0.01 - 2.54mm
(0.001 - 0.100 inches)
PECT: 0.63 - 508mm
(0.025 - 19.999 inches)
PECT: 0.01 - 2.54mm
(0.0005 - 0.100 inch) 

PE: 0.63 - 508mm
(0.025 - 19.999 inches)
PETP: 0.63 - 508mm
(0.025 - 19.999 inches)
EE: 1.27 - 102mm
(0.050 - 4.000 inches)
EEV: 1.27 - 25.4mm
(0.050 - 1.000 inch)
CT: 0.01 - 2.54mm
(0.001 - 0.100 inches)
PECT: 0.63 - 508mm
(0.025 - 19.999 inches)
PECT: 0.01 - 2.54mm
(0.0005 - 0.100 inch)

Measurement Accuracy

± 1% or ±0.1mm
whichever is the greater

± 1% or ±0.1mm
whichever is the greater

± 1% or ±0.1mm
whichever is the greater

± 1% or ±0.1mm
whichever is the greater

Measurement Resolution

0.01mm (0.001 inches)

0.01mm (0.001 inches)

0.01mm (0.001 inches)

0.01mm (0.001 inches)

Velocity Calibration Range

1250 - 13,995m/s
(0.0492 - 0.5510in/ms)

 1250 - 13,995m/s
(0.0492 - 0.5510in/ms)

 1250 - 13,995m/s
(0.0492 - 0.5510in/ms)

1250 - 13,995m/s
(0.0492 - 0.5510in/ms)

Additional Features:
High speed scan mode

Differential mode

Limit alarm mode

B-Scan display speed

15 seconds per screen

15 seconds per screen

 Adjustable display speed

Adjustable display speed

Flaw mode

 

 

Basic prove-up flaw detection using single element angle beam transducers

Basic prove-up flaw detection using single element angle beam transducers

Calibration setups

 6 factory & 64 user-definable setups transferrable to and from a PC archive

6 factory & 64 user-definable setups transferrable to and from a PC archive

6 factory & 64 user-definable setups transferrable to and from a PC archive 

6 factory & 64 user-definable setups transferrable to and from a PC archive

Gates

 

 

 3 fully adjustable gates: start, stop, width & threshold

3 fully adjustable gates: start, stop, width & threshold

Damping

 

 

 

Adjustable; impedance matching for optimising transducer performance

Pulser type

Dual square wave pulsers up to 140Hz pulse repetition rate

Dual square wave pulsers up to 140Hz pulse repetition rate  

Dual 200 volt square wave pulsers with adjustable pulse width(spike, thin, wide) and 50 volt cut/boost for greater penetration

Dual 200 volt square wave pulsers with adjustable pulse width
(spike, thin, wide) and 50 volt cut/boost for greater penetration

Gain

 Automatic gain control (AGC) with 110dB range (limited), or selectable gain: vlow, low, medium hi or vhi

Automatic gain control (AGC) with 110dB range (limited), or selectable gain: vlow, low, medium hi or vhi

Manual, automatic gain control (AGC) with 110dB range (limited)

Manual, automatic gain control (AGC) with 110dB range (limited)

Timing

Precision 25MHz TCXO with single shot 100MHz 8bit ultra low power 8 bit digitizer

Precision 25MHz TCXO with single shot 100MHz 8bit ultra low power 8 bit digitizer

Precision 25MHz TCXO with single shot 100MHz 8bit ultra low power 8 bit digitizer

Precision 25MHz TCXO with single shot 100MHz 8bit ultra low power 8 bit digitizer

Data logging

 

  • 16,000 with B-scan image & gauge settings
  • 210,000 - coating, material, min, max thickness
  • sequential and grid logging
  • Alpha numeric batch identification
  • OBSTRUCT indicates inaccessible locations
  • 16,000 with B-scan image & gauge settings
  • 210,000 - coating, material, min, max thickness
  • sequential and grid logging
  • Alpha numeric batch identification
  • OBSTRUCT indicates inaccessible locations
  • 8,000 with A/B-scan image & gauge settings
  • 210,000 - coating, material, min, max thickness
  • sequential and grid logging
  • Alpha numeric batch identification
  • OBSTRUCT indicates inaccessible locations

Calibration Options

Single, two point, velocity & material type

Single, two point, velocity & material type

Single, two point, velocity & material type

Single, two point, velocity & material type

Transducer Probe Type

 Dual element

Dual element

Dual element & flaw prove up

Dual element & flaw prove up

Transducer Frequency Range

1 - 10MHz 

1 - 10MHz 

1 - 10MHz 

1 - 10MHz

Transducer recognition

Automatic & manual - selectable from a list 

 Automatic & manual - selectable from a list 

Automatic & manual - selectable from a list  

Automatic & manual - selectable from a list 

V-path / dual path error correction

 Automatic

 Automatic

Automatic 

Automatic

Probe zero

Automatic & manual (via integrated probe disk)

Automatic & manual (via integrated probe disk) 

Automatic & manual (via integrated probe disk) 

Automatic & manual (via integrated probe disk)

Display

 1/8 VGA (grayscale)
62 x 45.7mm
(2.4 x 1.8 inches)
viewable area

1/8 VGA (grayscale)
62 x 45.7mm
(2.4 x 1.8 inches)
viewable area  

1/8 VGA (grayscale)
62 x 45.7mm
(2.4 x 1.8 inches)
viewable area  

1/4 VGA AMOLED colour display
57.6 x 43.2mm
(2.27 x 1.78inch)
viewable area

Display Refresh Rate

 25Hz

25Hz 

25Hz 

120Hz

Units (selectable)

 mm or inches

 mm or inches

mm or inches 

mm or inches

Backlight

on / off / auto

on / off / auto  

on / off / auto 

adjustable brightness

Repeatability / Stability Indicator

Battery Type

3 x AA alkaline

3 x AA alkaline

3 x AA alkaline

3 x AA alkaline

Battery Life (approximate)

150 hours

150 hours

50 hours

25 hours

Low Battery Indicator

Battery Save Mode

 auto

 auto

 auto

auto

Operating Temperature

 -10 to 60ºC (14 to 140ºF)

 -10 to 60ºC (14 to 140ºF)

 -10 to 60ºC (14 to 140ºF)

-10 to 60ºC (14 to 140ºF)

Size (w x h x d)

  • 质量承诺
  • 正品保修
  • 送货到家
  • 交易简单化