Calibration Range: 0.05 - 0.6 ppm
Measuring Range: 0.05 - 0.6 ppm
Sampling (flow) Rate:100mL/min
Sampling Volume: 1000mL
Sampling Time: min
Colour Change: Pink → White
Nr. of tests: 10
Automatic Gas Sampler: GSP-300FT-2
Detail
Specifications
Calibration Range | 0.05 - 0.6 ppm |
Measuring range | 0.05 - 0.6 ppm |
Sampling (flow) Rate | 100mL/min |
Sampling Volume | 1000mL |
Sampling Time | 10min. |
Detecting Limit | 0.02 ppm |
Colour Change | Pink → White |
Corrections for temperature/humidity | Unnecessary for 0 to 40ºC Unnecessary for R.H.10 to 90% |
Shelf life | 2 year |
Accuracy | CV=5-10% (CV: Coefficient of variation = σ: standard deviation / mean value x 100) |
Possibly coexisting substances and their interferences (NOTE)
Substance(s) | Interference | Colour change by itself |
Ammonia | 。�1/6 | 。シ | No |
Sulphur dioxide | 。シ | No | |
Nitrogen dioxide | No | No | |
Hydrogen sulphide | 。シ | No |
Calibration gas generation | Permeation tube method |
TLV-TWA | TLV-STEL | Explosive range |
0.5ppm | 1 ppm |