Indicator: 100 to 1800 ppm
Measuring Range:
+ 20 to 100 ppm, Number of Pump Strokes 4
+ 100 to 1800 ppm, Number of Pump Strokes 1
+ 1800 to 3600 ppm, Number of Pump Strokes 1/2
Sampling Time: 45 seconds per pump stroke
Colour Change: Purple → Yellow
Reaction Principle: SO2 + BaCl2 +H2O → BaSO3 + 2HC, HCl+Base → Chloride
Coefficient of Variation: 10% (100 ~ 600 ppm), 5% (600 ~ 1800 ppm)
Nr. of tests: 10
Pump: GV-100S/110S
Details
Catalog
Manual
Performance
Measuring Range |
20 to 100 ppm |
100 to 1800 ppm |
1800 to 3600 ppm |
|
Number of Pump Strokes |
|
Correction Factor |
|
Sampling Time |
45 seconds per pump stroke |
Detecting Limit |
4 ppm (n=4) |
Colour Change |
Purple → Yellow |
Reaction Principle |
SO2 + BaCl2 +H2O → BaSO3 + 2HCl HCl+Base → Chloride |
Coefficient of Variation |
10% (for 100 to 600 ppm), 5% (for 600 to 1800 ppm) |
Shelf Life |
3 Years |
Corrections for temperature & humidity |
Temperature correction is necessary |
Store the tubes at cool and dark place. |
Possible coexisting substances and their interferences
(NOTE)
Substance |
Concentration |
Interference |
Change colour by itself to |
Carbon monoxide, Nitric oxide |
|
No |
No |
Carbon dioxide |
|
No |
No |
Nitrogen dioxide |
≧ 1/10 |
+ |
White ( ≧ 600ppm) |
Hydrogen sulphide |
≧ 10 times |
 |
No |
Calibration gas generation |
High pressure gas cylinder method |
TLV-TWA |
TLV-STEL |
Explosive range |
- |
0.25 ppm (2014) |
- |