Indicator: 1 ~ 20 ppm
Measuring Range: 1 ~ 20 ppm
Sampling Time: 2 minute per pump stroke
Colour Change: Bluish purple→White
Reaction principle: SO2F2 → SO2, SO2 + l2 + H2O → HI + H2SO4
Nr. of tests: 4 tubes
Gas Sampler pump: GV-100S, GV-110S, Pyrotec Pyrolyzer 860
Detail
Performance
Measuring Range | 1 to 20 ppm |
Number of Pump Strokes | 3 |
Correction Factor | 1 |
Sampling Time | 2 minutes per pump stroke |
Detecting Limit | 0.4 (n=3) |
Colour Change | Bluish purple→White |
Reaction Principle | SO2F2 → SO2 SO2 + l2 + H2O → HI + H2SO4 |
Coefficient of Variation | 10% (for 1 to 20ppm) |
Shelf Life | 2 Years |
Corrections for temperature & humidity | Temperature correction is necessary |
Store the tubes at cool and dark place. |
Possible coexisting substances and their interferences (NOTE)
Substance | Concentration | Interference | Change colour by itself to |
Sulphur Dioxide | ≧0.04 ppm | + | White at 0.05 ppm |
Carbon Dioxide | ≦5 % | No | No |
Chloropicrin(CP) | ≦50ppm | No | No (![]() |
Methyl Isothiocyanate(MITC) | ≦50ppm | No | No (![]() |
Low Oxygen environment | + | No |
Calibration gas generation | Vaper pressure method |
TLV-TWA | TLV-STEL | Explosive range |
5ppm(2014) | 10ppm(2014) | -- |