Indicator: 0.02 ~ 0.6%
Measuring Range: 0.02 ~ 0.6%, Number of Pump Strokes 2
Sampling Time: 1.5 minute per pump stroke
Colour Change: Orange → Dark green
Reaction Principle: CH3COC2H5 + Cr6+ + H2SO4 + → Cr3+
Coefficient of Variation: 10% (for 0.02 to 0.2 %), 5% (for 0.2 to 0.6 %)
Nr. of tests: 10
Pump: GV-100S/110S
Detail
Performance
Measuring Range | 0.02 to 0.6% |
Number of Pump Strokes | 2 |
Correction Factor | 1 |
Sampling Time | 1.5 minutes per pump stroke |
Detecting Limit | 0.002% (n=2) |
Colour Change | Orange → Dark green |
Reaction Principle | CH3COC2H5 + Cr6+ + H2SO4 + → Cr3+ |
Coefficient of Variation | 10% (for 0.02 to 0.2 %), 5% (for 0.2 to 0.6 %) |
Shelf Life | 3 Years |
Corrections for temperature & humidity | Temperature correction is necessary |
Store the tubes at cool and dark place. |
Possible coexisting substances and their interferences (NOTE)
Substance | Concentration | Interference | Change colour by itself to |
sulphur dioxide | ![]() |
+ | Green(![]() |
Hydrogen sulphide | ![]() |
+ | Dark green(![]() |
Alcohols, Esters, Ketones | + | Dark green | |
Propane | ![]() |
Yes | Dark green (whole layer)(![]() |
Aromatic HCs. | ![]() |
+ | Dark green(![]() |
Calibration gas generation | Static gas dilution method |
TLV-TWA | TLV-STEL | Explosive range |
200 ppm (2014) | 300 ppm (2014) | 1.7 to 11.4% |
- 质量承诺
- 正品保修
- 送货到家
- 交易简单化