FLUKE i30s AC/DC钳形表 (30mA~30ADC, 30mA~20AACrms)
制造商: FLUKE Model: i30s P/N: 2584935 - 报价要求
- 联系
Electrical specifications
Specified current range: 30 mA to 30 A DC, 30 mA to 20 A AC rms
Usable current range: 5 mA to 30 A DC, 30 mA to 20 A AC rms
Crest factor: 1.4 in
Output sensitivity: 100 mV/A
Accuracy (at +25°C): ±1% of reading ±2 mA
Resolution: ±1 mA
Load impedance: > 100 kΩ
Conductor position sensitivity: ±1% relative to center reading
Frequency range: DC to 100 kHz (-0.5 dB)
Phase shift below 1 kHz: < 2°
Temperature coefficient: ±0.01% of reading / °C
Power supply: 9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
Working voltage (see Safety Standards section): 300 V AC rms or DC
General Specifications
Maximum conductor size: 19 mm diameter
Output connection: Safety BNC connector, supplied with safety 4 mm adapter
Output zero: Manual adjust via thumbwheel
Cable length: 2 m
Operating temperature range: 0°C to +50°C
Storage temperature range (with battery removed): -20°C to +85°C
Operating humidity: 15% to 85% (non-condensing)
Weight: 250 g
Safety: IEC 61010-1, Pollution Degree 2
IEC 61010-2- 032: CAT III 300V
Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc andfrequencies below 1 kHz.
EMC Compatibility: IEC 61326-1: Portable Electromagnetic Environment
- 质量承诺
- 正品保修
- 送货到家