Technical Specifications
|
Display
|
|
Resolution
|
|
V DC
|
Ranges:
|
100 mV to 1000 V
|
Max. Resolution:
|
100 nV
|
Accuracy:
|
8845A: 0.0035 + 0.0005 (% measurement + % of range)
|
|
8846A: 0.0024 + 0.0005 (% measurement + % of range)
|
|
V AC
|
Ranges:
|
8845A: 100 mV to 750 V
|
|
8846A: 100 mV to 1000 V
|
Max. Resolution:
|
100 nV
|
Accuracy:
|
8845A: 0.06 + 0.03 (% measurement + % of range)
|
|
8846A: 0.06 + 0.03 (% measurement + % of range)
|
Frequency:
|
3 Hz to 300 KHz
|
|
Resistance
|
2x4 Wire:
|
Yes
|
Ranges:
|
8845A: 100 Ω to 100 MΩ
|
|
8846A: 10 Ω to 1 GΩ
|
Max. Resolution:
|
8845A: 100 μΩ
|
|
8846A: 10 μΩ
|
Accuracy:
|
8845A: 0.010 + 0.001 (% measurement + % of range)
|
|
8846A: 0.010 + 0.001 (% measurement + % of range)
|
|
A DC
|
Ranges:
|
100 μA to 10 A
|
Max. Resolution:
|
100 pA
|
Accuracy:
|
0.050 + 0.005 (% measurement + % of range)
|
|
A AC
|
Ranges:
|
8845A: 10 mA to 10 A
|
|
8846A: 100 mA to 10 A
|
Max. Resolution:
|
8845A: 10 nA
|
|
8846A: 100 pA
|
Accuracy:
|
0.10 + 0.04 (% measurement + % of range)
|
Frequency:
|
3 Hz to 10 kHz
|
|
Freq/Period
|
Ranges:
|
8845A: 3 Hz to 300 kHz
|
|
8846A: 3 Hz to 1 MHz
|
Max. Resolution:
|
1 μHz
|
Accuracy:
|
0.01 %
|
|
Continuity/ Diode Test
|
|
Capacitance
|
Ranges:
|
8846A: 1 nF to 0.1 F
|
Max. Resolution:
|
8846A: 1 pf
|
Accuracy:
|
8846A: 1 %
|
|
Temperature
|
Type:
|
8846A: Platinum RTD
|
Ranges:
|
8846A: -200 °C to +600 °
|
Max. Resolution:
|
8846A: 0.01 °
|
Accuracy:
|
8846A: 0.06 °
|
|
Math Functions
|
|
NULL, Min/Max/Average, Std Dev
|
dB/dBm:
|
Yes
|
|
Advanced Functions
|
Statistics/Histogram:
|
Yes
|
Trendplot:
|
Yes
|
Limit Test:
|
Yes
|
|
Input Output
|
USB Memory:
|
8846A: USB memory drive port
|
Real Time Clock:
|
8846A: Yes
|
Interfaces:
|
RS 232, IEE-488.2, Ethernet, USB (with optional adaptor)
|
Programming Languages/Modes:
|
8846A: SCPI (IEEE-488.2), Agilent 34401A, Fluke 45
|
|